Users Guide

Disable
java –jar dell_OMC_ITNM_ConfigUtility_v_3_0.jar -<option>=<value>
For example:
java –jar dell_OMC_ITNM_ConfigUtility_v_3_0.jar -monitorinband=enable
java –jar dell_OMC_ITNM_ConfigUtility_v_3_0.jar -monitorinband=disable
NOTE: If an ESXi system has IPv4 and IPv6 addresses and both of them are discovered, the
addresses appear as different managed nodes under the
Dell OEM DevicesServersESXi
Servers
. You can avoid the redundant service tag by excluding these IP addresses in the discovery
configuration.
If the IPv6 address of a Dell OEM server running ESXi is configured as a seed in ITNM IP Edition, then
the trap association will not occur. To view the trap association, discover the Dell OEM servers
running ESXi using an IPv4 address.
Discovering and classifying 10th to 13th generation of
Dell PowerEdge servers
To discover Dell PwerEdge servers, ensure that the DellServerSNMP discovery agent is enabled for
discovering Dell servers running Windows and Linux operating systems and the DellServerWsman
discovery agent is enabled for servers running VMware ESXi operating systems.
The discovered Dell servers are classified under the following class names:
DellServerMonolithicLinux — For monolithic servers running Linux operating systems
DellServerModularWindows — For modular servers running Windows operating systems
DellServerModularLinux — For modular servers running Linux operating systems
DellServerMonolithicWindows — For monolithic servers running Windows operating systems
DellServerModularESXi — For modular servers running ESXi operating systems
DellServerMonolithicESXi — For monolithic servers running ESXi operating systems
In the left pane on the Tivoli Integrated Portal (TIP), click AvailabilityNetwork AvailabilityNetwork
ViewsDell Managed Systems. The Dell Managed Systems pane is displayed on the right-hand side.
For more information, see Viewing Dell devices.
NOTE: If you are discovering Dell PowerEdge servers or Dell PowerVault NX Storage Arrays running
ESXi version 5.5 or later, configure the environment variable DELL_OMC_ITNM_JAVA_PATH using
JRE version 1.6.0_18 (6u18) or later.
By default, for the 12th or later generation of Dell PowerEdge servers, Dell PowerVault NX Storage Arrays,
or Dell workstations in-band server discovery is enabled. When you use both in-band and OOB discovery
methods for those devices, they may create redundant information. You can avoid the redundant
information by disabling the in-band discovery. The discovery can be controlled using a configured value.
The discovery and classification is based on the values:
Enable
Disable
java –jar dell_OMC_ITNM_ConfigUtility_v_3_0.jar -<option>=<value>
20