Users Guide
Dell EqualLogic events are not correlated
Verify that the following triggers are enabled on Netcool/OMNIbus ObjectServer:
• dell_equallogic_clear
• dell_equallogic_deduplicate_clear
Dell Enterprise (S-Series, M-Series, Z-Series, and C-
Series) events are not correlated
Verify that the following triggers are enabled on Netcool/OMNIbus ObjectServer:
• dell_enterprise_switch_clear
• dell_enterprise_switch_deduplicate_clear
Dell N-Series events are not correlated
Verify that the following triggers are enabled on Netcool/OMNIbus ObjectServer:
• dell_nseries_clear
• dell_nseries_deduplicate_clear
Error while importing the Web GUI Integrations
Restart the Web GUI server after importing the Dell OpenManage Connection to the ObjectServer.
Error while launching the Dell consoles using Web GUI
• Verify that Perl is properly installed on the Web GUI server.
• For the prerequisites for enabling the CGI scripts functionality, see the IBM Tivili Netcool/OMNIbus CGI script documents.
Error while launching the Dell PowerVault MD Storage
Array console using Web GUI
• Make sure that Dell PowerVault Modular Disk Storage Array is installed.
• Make sure that the path of the Dell PowerVault Modular Disk Storage Array Installer is specied in the Dell PowerVault Modular Disk
Storage Array console launch tool.
Error in restarting the MTTrapd probe in Windows
Ensure that the commented text (if it exists) is not at the end in the following les:
• dell.master.include.lookup
• dell.master.include.rules
Troubleshooting