Users Guide

include "$NC_RULES_HOME/include-snmptrap/dell/
dell.Nseriesswitch.master.include.snmptrap.lookup"
3 Verify that the following entries are included in the dell.master.include.rules le:
include "$NC_RULES_HOME/include-snmptrap/dell/
dell.Nseriesswitch.master.include.snmptrap.rules"
Dell W-Series switch events are not received at the
Netcool/OMNIbus console
1 Verify that the following entries are included in the SNMP probe rules le:
include "$NC_RULES_HOME/include-snmptrap/dell/dell.master.include.rules"
include "$NC_RULES_HOME/include-snmptrap/dell/dell.master.include.lookup"
2 Verify that the following entries are included in the dell.master.include.lookup le:
include "$NC_RULES_HOME/include-snmptrap/dell/
dell.Wseriesswitch.master.include.snmptrap.lookup"
3 Verify that the following entries are included in the dell.master.include.rules le:
include "$NC_RULES_HOME/include-snmptrap/dell/
dell.Wseriesswitch.master.include.snmptrap.rules"
Dell OpenManage Server Administrator events are not
correlated
Verify that the following triggers are enabled in Netcool/OMNIbus ObjectServer:
dell_omsa_clear
dell_omsa_deduplicate_clear
iDRAC7/iDRAC8 Events not Correlated
Verify that the following triggers are enabled in Netcool/OMNIbus ObjectServer:
dell_idrac_clear
dell_idrac_deduplicate_clear
Dell FX2 CMC or VRTX CMC events are not
correlated
Verify that the following triggers are enabled on Netcool/OMNIbus ObjectServer:
dell_cmc_clear
dell_cmc_deduplicate_clear
Compellent events are not correlated
Verify that the following triggers are enabled in Netcool/OMNIbus ObjectServer:
dell_compellent_clear
dell_compellent_deduplicate_clear
40