Users Guide

Duplicated problem event with another problem event — OMSA, Compellent storage arrays, EqualLogic storage arrays, PowerVault MD
storage arrays, Enterprise Series Switches, N-Series Switch, and DCLM events support this event correlation.
The dell_omsa_deduplicate_clear trigger correlates the OMSA problem events.
The dell_equallogic_deduplicate_clear trigger correlates the EqualLogic storage array problem events.
The dell_dclm_deduplicate_clear trigger correlates the DCLM problem polled events.
NOTE: This trigger is applicable only if IBM Tivoli Netcool/Omnibus is integrated with ITNM and the Dell OpenManage
Connection for IBM Tivoli Network Manager is installed.
The dell_mdarray_deduplicate_clear trigger correlates the PowerVault MD Storage Array problem polled events.
The dell_idrac_deduplicate_clear trigger correlates the iDRAC7 or iDRAC8 problem events.
The dell_compellent_deduplicate_clear trigger correlates the Compellent storage array problem events.
The dell_enterprise_switch_deduplicate_clear trigger correlates the S-Series, M-Series, Z-Series, and C-Series switch
problem events.
The dell_nseries_deduplicate_clear trigger correlates the N-Series switch problem events.
Event auto correlation support is not available between legacy and enhanced event message format traps for in-band Dell servers.
The normal-to-normal event correlation is not supported as Netcool/OMNIbus periodically clears the normal events.
For more information on OMSA and OMSS event correlation, see Dell OpenManage Server Administrator Messages Reference Guide at
dell.com/support/home.
Dell OMSA Alert Groups
The OpenManage Server Administrator (OMSA) alerts are the events generated by OMSA and displayed on the Netcool/OMNIbus
console. The following table lists the OMSA alerts.
Table 18. Dell OMSA Alert Groups
Alert Group Description
ACPowerCord Provides status information for power cords of an AC power switch on systems that
support AC switching.
AmperageProbe Provides status information for current sensors in a particular chassis.
Battery Provides status information for batteries in a particular chassis.
ChassisIntrusion Provides notication when a chassis is intruded.
CoolingDevice Provides status information for fans in a particular chassis.
Device Provides status and error information when some devices, such as memory cards are
added or removed.
FanEnclosure Monitors if foreign objects are present in an enclosure and the duration a fan enclosure
is missing from a chassis.
HardwareLog Provides status and warning information about the non-circular logs that may ll up,
resulting in lost status messages.
IDSDModuleMedia Provides the status information about the Internal Dual SD Module.
18 Using the Dell OpenManage Connection for IBM Tivoli Netcool/OMNIbus