Setup Guide
OOB Server (iDRAC8, iDRAC7) traps
a Uncomment the dell-IDRAC-MIB.include.snmptrap.lookup le include statement in the dell.master.include.lookup
le.
b Uncomment the dell-IDRAC-MIB.include.snmptrap.rules le include statement in the dell.master.include.rules le.
FX2 CMC, VRTX CMC, CMC , iDRAC6, DRAC5 traps
a
Uncomment the dell-RAC-MIB.include.snmptrap.lookup le include statement in the dell.master.include.lookup le.
b Uncomment the dell-RAC-MIB.include.snmptrap.rules le include statement in the dell.master.include.rules le.
Compellent Storage Array traps
a Uncomment the dell-STORAGE-SC-MIB.include.snmptrap.lookup le include statement in the
dell.master.include.lookup le.
b Uncomment the dell-STORAGE-SC-MIB.include.snmptrap.rules le include statement in the
dell.master.include.rules le.
EqualLogic traps
a Uncomment the equalLogic-EQLMEMBER-MIB.include.snmptrap.lookup le include statement in the
dell.master.include.lookup le.
b Uncomment the equalLogic-EQLDISK-MIB.include.snmptrap.lookup le include statement in the
dell.master.include.lookup le.
c Uncomment the equalLogic-SCSI-MIB.include.snmptrap.lookup le include statement in the
dell.master.include.lookup le.
d Uncomment the equalLogic-EQLMEMBER-MIB.include.snmptrap.rules le include statement in the
dell.master.include.rules le.
e Uncomment the equalLogic-EQLDISK-MIB.include.snmptrap.rules le include statement in the
dell.master.include.rules le.
f Uncomment the equalLogic-SCSI-MIB.include.snmptrap.rules le include statement in the
dell.master.include.rules le.
g Uncomment the equalLogic-ISCSI-MIB.include.snmptrap.rules le include statement in the
dell.master.include.rules le.
PowerVault MD Storage Array traps
a Uncomment the dell-MDStorageArray-MIB.include.snmptrap.lookup le include statement in the
dell.master.include.lookup le.
b Uncomment the dell-MDStorageArray-MIB.include.snmptrap.rules le include statement in the
dell.master.include.rules le.
Dell Network Switch traps
• S-Series, M-Series, Z-Series, and C-Series Switches
1 Uncomment the dell.switch.master.include.lookup le include statement in the dell.master.include.lookup le.
2 Uncomment the dell.switch.master.include.rules le include statement in the dell.master.include.rules le.
• N-Series Switches
1 Uncomment the dell.Nseriesswitch.master.include.lookup le include statement in the
dell.master.include.lookup le.
2 Uncomment the dell.Nseriesswitch.master.include.rules le include statement in the
dell.master.include.rules le.
• W-Series Switches
1 Uncomment the dell.Wseriesswitch.master.include.lookup le include statement in the
dell.master.include.lookup le.
14
Installing Dell OpenManage Connection for Netcool/OMNIbus