Netcool/OMNIbus 控制台接收不到 Dell PowerEdge 服务
器、
PowerVault NX 存储阵列和工作站事件
1. 验证 SNMP 探测规则文件包含下列条目:
• include "$NC_RULES_HOME/include-snmptrap/dell/dell.master.include.rules"
• include "$NC_RULES_HOME/include-snmptrap/dell/dell.master.include.lookup"
2. 验证 dell.master.include.lookup 文件包含下列条目:
• include "$NC_RULES_HOME/include-snmptrap/dell/dell-MIB-Dell-
10892.include.snmptrap.lookup"
• include "$NC_RULES_HOME/include-snmptrap/dell/dell-StorageManagement-
MIB.include.snmptrap.lookup"
3. 验证 dell.master.include.rules 文件包含下列条目:
• include "$NC_RULES_HOME/include-snmptrap/dell/dell-MIB-Dell-
10892.include.snmptrap.rules"
• include "$NC_RULES_HOME/include-snmptrap/dell/dell-StorageManagement-
MIB.include.snmptrap.rules"
Netcool/OMNIbus 控制台接收不到 Dell iDRAC7 和 iDRAC8
服务器事件
1. 验证 SNMP 探测规则文件包含下列条目:
• include "$NC_RULES_HOME/include-snmptrap/dell/dell.master.include.rules"
• include "$NC_RULES_HOME/include-snmptrap/dell/dell.master.include.lookup"
2. 验证 dell.master.include.lookup 文件包含下列条目:
include "$NC_RULES_HOME/include-snmptrap/dell/dell-IDRAC-
MIB.include.snmptrap.lookup"
3. 验证 dell.master.include.rules 文件包含下列条目:
include "$NC_RULES_HOME/include-snmptrap/dell/dell-IDRAC-
MIB.include.snmptrap.rules"
Netcool/OMNIbus 控制台接收不到 Dell CMC、VRTX CMC
和 DRAC 事件
1. 验证 SNMP 探测规则文件包含下列条目:
• include "$NC_RULES_HOME/include-snmptrap/dell/dell.master.include.rules"
• include "$NC_RULES_HOME/include-snmptrap/dell/dell.master.include.lookup"
2. 验证 dell.master.include.lookup 文件包含下列条目:
include "$NC_RULES_HOME/include-snmptrap/dell/dell-RAC-
MIB.include.snmptrap.lookup"
3. 验证 dell.master.include.rules 文件包含下列条目:
include "$NC_RULES_HOME/include-snmptrap/dell/dell-RAC-
MIB.include.snmptrap.rules"
36