Owner's Manual

1. Copy the dell_OMNIbus_Connection_SNMP_Configurator_v_2_0.jar,
dell_OMNIbus_Connection_SNMP_Helper_v_2_0.jar, snmp4j-2.1.0.jar, and dell_config.properties files in the
%OMNIHOME% directory on the system where you have installed the desktop client.
NOTE: On systems running Linux, use the $OMNIHOME directory.
2. In the %OMNIHOME% directory on the system where you have installed the desktop client, copy the files:
dellserver_int_desktop.ver — for server integration
dellserveridrac_int_desktop.ver — for iDRAC integration
dellcmc_int_desktop.ver — for CMC integration
3. Configure the SNMP Community using the Dell SNMP Configurator utility. For more information, see SNMP
Configurator Utility.
Installing Web GUI Integration
The import sub folder within the webgui_integration folder contains the following files and sub folders:
config — Contains the cgi-bin folder with the following files:
omsalauncher_linux.cgi
omsalauncher_nt.cgi
idraclauncher_linux.cgi
idraclauncher_nt.cgi
cmclauncher_linux.cgi
cmclauncher_nt.cgi
dell_config.properties — Contains the encrypted SNMP community string.
dell_OMNIbus_Connection_SNMP_Configurator_v_2_0.jar — Configures the SNMP community name string.
dell_OMNIbus_Connection_SNMP_Helper_v_2_0.jar — Launches the OpenManage Server Administrator
(OMSA), Integrated Dell Remote Access Controller (iDRAC), and Dell CMC URLs.
dellserver_int_webgui.ver — Version file for Server Administrator web GUI integration.
dellcmc_int_webgui.ver — Version file for Dell CMC web GUI integration.
dellserveridrac_int_webgui.ver — Version file for iDRAC web GUI integration
dellcommontools_int_webgui.ver — Version file for Dell OME web GUI integration
export.xml — Exports menus and tools and for registering cgi scripts.
snmp4j-2.1.0.jar — SNMP Helper uses this file to establish the SNMP Communication with Dell devices.
To deploy the Dell integration components on the system that hosts the web GUI:
1. Copy the dell_OMNIbus_Connection_SNMP_Configurator_v_2_0.jar,
dell_OMNIbus_Connection_SNMP_Helper_v_2_0.jar, snmp4j-2.1.0.jar , and dell_config.properties files in the <Web
GUI home directory> on the system where you have installed the web GUI component.
2. Configure the SNMP Community using the Dell SNMP Configurator utility. For more information, see SNMP
Configurator Utility.
3. On the system where the web GUI component is installed, in the <Web GUI home directory>, copy the files:
dellserver_int_webgui.ver — server integration
dellserveridrac_int_webgui.ver — Dell OOB server
dellcmc_int_webgui.ver — Dell CMC Integration
dellcommontools_int_webgui.ver — Dell Common Tools Integration
4. Navigate to the import folder in the location where you have extracted webgui_integration folder and run the
following command for each integration:
16