Owner's Manual

22 Troubleshooting
Dell EqualLogic Events Not Received at the
Netcool/OMNIbus Console
Verify that the following entries are included in the SNMP probe rules file:
include "$NC_RULES_HOME/include-
snmptrap/dell/dell.master.include.rules"
include "$NC_RULES_HOME/include-
snmptrap/dell/dell.master.include.lookup"
Verify that the following entries are included in the
dell.master.include.lookup
file:
include "$NC_RULES_HOME/include-
snmptrap/dell/equalLogic-EQLMEMBER-
MIB.include.snmptrap.lookup"
include "$NC_RULES_HOME/include-
snmptrap/dell/equalLogic-EQLDISK-
MIB.include.snmptrap.lookup"
Verify that the following entries are included in the
dell.master.include.rules
file:
include "$NC_RULES_HOME/include-
snmptrap/dell/equalLogic-EQLMEMBER-
MIB.include.snmptrap.rules"
include "$NC_RULES_HOME/include-
snmptrap/dell/equalLogic-EQLDISK-
MIB.include.snmptrap.rules"
Dell OpenManage Server Administrator Events
Not Correlated
Verify that the following triggers are enabled in Netcool/OMNIbus
ObjectServer:
dell_omsa_clear
dell_omsa_deduplicate_clear