22 Troubleshooting and Frequently Asked Questions
Not Receiving Alerts
If the management station is not receiving alerts, ensure that:
• Network connectivity to the managed system exists; confirm by eliciting
a
ping
response.
• The Dell OpenManage Server Administrator (OMSA) is installed and
running on the managed system .
• The SNMP agent and trap services are initiated on the managed system.
• The OpenManage Server Administrator (OMSA) services are initiated on
the managed system.
• SNMP is configured on the managed system to send traps to the
management station's IP address.
• The SNMP community name and security (read/write community names)
are set properly on the managed system and that they correspond with that
of the CA management station.
• If you are not receiving RAC alerts, execute the
opreload
command in the
EM Message Console using the following steps:
a
Select from the following options given below depending on the
OpenManage Connection versions:
• If the OpenManage Connection version is CA NSM r11.1 SP2,
then click the
Start
button and select
Programs
All Programs
CA
Unicenter
NSM
Enterprise Management
EM
Classic.
• If the OpenManage Connection versions are CA NSM r11.2
CUM1, CA NSM r11.2 SP1 or CA NSM r11.2 SP2, then click the
Start
button and select
Programs
All Programs
Compute
Associates
Unicenter
NSM
Enterprise Management
EM Classic.
b
Double-click
Windows
.
c
Double-click
Event
.
d
Double-click
Console Logs
.
e
At the Console Logs command field, type
opreload
.
RAC events are displayed in the console log.