Setup Guide
column="eqlMemberIndex"/> <dataField tableAlias="d" dataType="str"
column="eqlGroupIP"/> <dataField tableAlias="d" dataType="str"
column="eqlStoragePool"/> <fromTables> FROM _ncim_.delldevicemaster d INNER
JOIN _ncim_.entityDetails ed ON ed.entityId=d.entityId WHERE d.entityId = ? </
fromTables> </entityMetaData> // Dell specified changes - END
topoviz.properties의 Dell 특정 변경 사항
// Dell specified changes - START topoviz.image.DellServerMonolithic =
dell_monolithic.svg topoviz.image.DellServerModular = dell_modular.svg
topoviz.image.DellCMC = dell_cmc.svg topoviz.image.DellDRAC5 = dell_drac5.svg
topoviz.image.DelliDRAC6 = dell_idrac6.svg topoviz.image.DelliDRAC7 =
dell_idrac7.svg topoviz.image.DellEqualLogic = dell_equallogic.svg
topoviz.image.DellMDArray = dell_mdarray.svg topoviz.image.DellVRTXCMC =
dell_vrtxcmc.svg topoviz.image.DelliDRAC8 = dell_idrac8.svg
topoviz.image.DellWorkstationRack topoviz.image.DellZSeriesSwitch
topoviz.image.DellMSeriesSwitch = dell_mseriesswitch.svg
topoviz.image.DellCompellent = dell_compellent.svg = dell_precisionrack.svg
topoviz.image.DellCSeriesSwitch = dell_cseriesswitch.svg
topoviz.image.DellSSeriesSwitch = dell_sseriesswitch.svg =
dell_zseriesswitch.svg topoviz.image.DellFX2CMC topoviz.image.DellNSeriesSwitch
topoviz.image.DellPowerVaultNX = dell_powervaultnx.svg
topoviz.image.DellWSeriesMobilityController = dell_wseriesswitch.svg =
dell_fx2cmc.svg = dell_nseriesswitch.svg// Dell specified changes - END
ip_default.xml의 Dell 특정 변경 사항
<container id="DellManagedSystems" label="Dell Managed Systems">
// Dell specified changes - START <container id="DellManagedSystems"
label="Dell Managed Systems"> <container id="DellServers" label="Dell Servers">
<dynamicDistinct id="MonolithicServers" label="Monolithic Servers"
connectivity="ipsubnets" endNodes="true"> <tableField
table="dellmonolithicservers" field="servicetag"/> </dynamicDistinct
<dynamicDistinct id="ModularServers" label="Modular Servers"
connectivity="ipsubnets" endNodes="true"> <tableField
table="dellmodularservers" field="servicetag"/> </dynamicDistinct>
<dynamicDistinct id="WindowsServers" label="Windows Servers"
connectivity="ipsubnets" endNodes="true"> <tableField
table="dellwindowsservers" field="servicetag"/> </dynamicDistinct>
<dynamicDistinct id="LinuxServers" label="Linux Servers"
connectivity="ipsubnets" endNodes="true"> <tableField table="delllinuxservers"
field="servicetag"/> </dynamicDistinct> <dynamicDistinct id="ESXiServers"
label="ESXi Servers" connectivity="ipsubnets" endNodes="true"> <tableField
table="dellesxiservers" field="servicetag"/> </dynamicDistinct> </container>
<container id="DellStorage" label="Dell Storage"> <filtered id="MDArrays"
label="PowerVault MD Storage" connectivity="ipsubnets" endNodes="true"> <filter
schema="ncim" table="chassis" filter="className in
('DellMDArray','DellMDArraySNMP')"/> </filtered> <dynamicDistinct
id="EqualLogic" label="EqualLogic PS-Series Storage" connectivity="ipsubnets"
endNodes="true"> <tableField table="dellequallogic" field="eqlGroupIp"/>
<tableField table="dellequallogic" field="eqlStoragePool"/> </dynamicDistinct>
<dynamicDistinct id="Compellent" label="Compellent Storage"
connectivity="ipsubnets" endNodes="true"> <tableField table="dellcompellent"
field="eqlGroupIp"/> </dynamicDistinct> <dynamicDistinct id="PowerVaultNX"
label="PowerVault NX Storage" connectivity="ipsubnets" endNodes="true">
<tableField table="dellpowervaultnx" field="servicetag"/> </dynamicDistinct></
container> <container id="DellChassis" label="Dell Chassis"> <dynamicDistinct
id="CMC" label="CMC" connectivity="ipsubnets" endNodes="true"> <tableField
table="dellcmc" field="chassistag"/> <tableField table="dellcmc"
field="servicetag"/> </dynamicDistinct> <dynamicDistinct id="VRTXCMC"
35