Setup Guide

Dell Dell.aoc 指定的更改
// Dell specified changes START active object 'Dell' { super_class =
'NetworkDevice'; instantiate_rule = "EntityOID like '1\.3\.6\.1\.4\.1\.674\.'
OR EntityOID like '1\.3\.6\.1\.4\.1\.1981\.'"; visual_icon =
'NetworkDevice'; }; // Dell specified changes - END
Dell DellSNMP.aoc 指定的更改
// Dell specified changes START active object 'DellSNMP' { super_class =
'Dell'; instantiate_rule = "EntityOID = '1.3.6.1.4.1.674.10892.2' OR EntityOID
= '1.3.6.1.4.1.674.10892.5' OR EntityOID = '1.3.6.1.4.1.674.10893.2.31' OR
EntityOID like '1\.3\.6\.1\.4\.1\.674\.10895' "; visual_icon =
'NetworkDevice'; }; // Dell specified changes - END
Dell ClassSchema.cfg 指定的更改
// Dell specified changes START insert into class.classIds values (17950,
'DellServerMonolithicWindows'); insert into class.classIds values (17951,
'DellServerMonolithicLinux'); insert into class.classIds values (17952,
'DellServerModularWindows'); insert into class.classIds values (17953,
'DellServerModularLinux'); insert into class.classIds values (17954,
'DellCMC'); insert into class.classIds values (17956, 'DellDRAC5'); insert into
class.classIds values (17957, 'DelliDRAC6'); insert into class.classIds values
(17958, 'DelliDRAC7'); insert into class.classIds values (17959,
'DellEqualLogic'); insert into class.classIds values (17960,
'DellServerMonolithicESXi'); insert into class.classIds values (17961,
'DellServerModularESXi'); insert into class.classIds values (17962,
'DellMDArray'); insert into class.classIds values (17963, 'DellVRTXCMC');
insert into class.classIds values (17964, 'DellFX2CMC'); insert into
class.classIds values (17965, 'DellCompellent'); insert into class.classIds
values (17966, 'DellWorkstationWindows'); insert into class.classIds values
(17967, 'DellWorkstationLinux'); insert into class.classIds values (17968,
'DellWorkstationESXi'); insert into class.classIds values (17979,
'DelliDRAC8'); insert into class.classIds values (17980, 'DellMDArraySNMP');
insert into class.classIds values (17981, 'DellMSeriesSwitch'); insert into
class.classIds values (17982, 'DellZSeriesSwitch'); insert into class.classIds
values (17983, 'DellSSeriesSwitch'); insert into class.classIds values (17984,
'DellCSeriesSwitch'); insert into class.classIds values (17985,
'DellNSeriesSwitch'); insert into class.classIds values (17986,
'DellWSeriesMobilityController'); insert into class.classIds values (17987,
'DellPowerVaultNX'); // Dell specified changes - END
Dell DbEntityDetails.domain.cfg 指定的更改
// Dell specified changes START insert into dbModel.entityMap
( EntityFilter, TableName, FieldMap ) values ( "(EntityType = 1 or EntityType =
8) and (ExtraInfo->m_Dell->m_ProductType is not NULL)", "delldevicemaster",
{ entityid = "eval(int, '&ObjectId')", classname = "eval(text, '&ClassName')",
servicetag = "eval(text, '&ExtraInfo->m_Dell->m_ServiceTag')", chassistag =
"eval(text, '&ExtraInfo->m_Dell->m_ChassisServiceTag')", producttype =
"eval(text, '&ExtraInfo->m_Dell->m_ProductType')", osname = "eval(text,
'&'ExtraInfo->m_Dell->m_OSName')", eqlMemberIndex = "eval(text,
'&ExtraInfo>m_Dell->m_EqlMemberIndex')", eqlGroupIP = "eval(text,
'&ExtraInfo>m_Dell->m_EqlGroupIP')", eqlStoragePool = "eval(text,
'&ExtraInfo>m_Dell->m_EqlStoragePool')", cmcservicetags = "eval(text,
34