Reference Guide

Property Description
NOTE: The Name property of ManagedSystemElement is also
defined as a user-friendly name. But, it is often subclassed to
be a Key. It is not reasonable that the same property can
convey both identity and a user-friendly name, without
inconsistencies. Where Name exists and is not a Key (such as
for instances of LogicalDevice), the same information can be
present in both the Name and ElementName properties.
ErrorInfo
An integer enumeration describing the type of error that occurred
most recently. For example, single (value=6) or double bit errors (7)
can be specified using this property. The values, 12-14, are
undefined in the CIM Schema since in DMI, they mix the semantics
of the type of error and whether it was correctable or not. The latter
is indicated in the property, CorrectableError.
Possible values are:
0 = Unknown
1 = Other
2 = OK
3 = Bad Read
4 = Parity Error
5 = Single-Bit Error
6 = Double-Bit Error
7 = Multi-Bit Error
8 = Nibble Error
9 = Checksum Error
10 = CRC Error 32768 = DIMM Disabled via Spare Activation
StartingAddress
Specifies the address of the memory error. The type of error is
described by the ErrorInfo property. If the ErrorInfo property is
equal to 3, "OK", then this property has no meaning.
SystemCreationClassName
The scoping System's CreationClassName.
SystemName
The scoping System's Name.
DCIM_IdentityContext
Property Description
ElementInContext
An Identity whose context is defined.
ElementProvidingContext
The ManagedElement that provides context or scope for the
Identity.
DCIM_OrderedComponent
Property
Description
AssignedSequence
AssignedSequence is an unsigned integer 'n' that
indicates the relative order of ManagedElement instances.
When 'n' is a positive integer, it indicates a place in the
256