Reference Guide
Property Description
• 5 = OK - The element is fully functional and is
operating within normal operational parameters
and without error.
• 10 = Degraded/Warning - The element is in
working order and all functionality is provided.
However, the element is not working to the best
of its abilities. For example, the element may not
be operating at optimal performance or it may be
reporting recoverable errors.
• 15 = Minor failure - All functionality is available
but some may be degraded.
• 20 = Major failure - The element is failing. It is
possible that some or all of the functionality of
this component is degraded or not working.
• 25 = Critical failure - The element is non-
functional and recovery may not be possible.
• 30 = Non-recoverable error - The element has
completely failed, and recovery is not possible.
All functionality provided by this element has
been lost.
• .. = DMTF Reserved
DMTF has reserved the unused portion of the continuum
for additional HealthStates in the future.
LowerThresholdCritical
The Sensor's threshold values specify the ranges (min
and max values) for determining whether the Sensor is
operating under Normal, NonCritical or Critical
conditions. The CurrentState is Critical once the
CurrentReading is below LowerThresholdCritical.
LowerThresholdNonCritical
The Sensor's threshold values specify the ranges (min
and max values) for determining whether the Sensor is
operating under Normal, NonCritical, Critical conditions. If
Current Reading is between LowerThresholdNonCritical
and Upper ThresholdNonCritical, then the Sensor is
reporting a normal value. If CurrentReading is between
LowerThresholdNonCritical and LowerThresholdCritical,
then the CurrentState is NonCritical.
Example for Set command: wmic /namespace:\\root\dcim
\sysman path dcim_numericsensor Where "ElementName
like '%Temperature Sensor:%'" set
LowerThresholdNonCritical=30. This sets the all
temperature probes (lower threshold non critical) in the
system to 30 degree Celsius.
OperationalStatus
Indicates the current statuses of the element. Various
operational statuses are defined. Many of the
enumeration's values are self-explanatory.
Possible values are:
• 0 = Unknown
• 1 = Other
• 2 = OK
• 3 = Degraded
• 4 = Stressed - Indicates that the element is
functioning, but needs attention. Examples of
132