Reference Guide
Property Description
Status
This property indicates the current status of the logical device.
Possible values are:
• 0 = OK
• 1 = Error
• 2 = Degraded
• 3 = Unknown
• 4 = Pred Fail
• 5 = Starting
• 6 = Stopping
• 7 = Service
• 8 = Stressed
• 9 = NonRecover
• 10 = No Contact
• 11 = Lost Comm
• 12 = Stopped
SystemCreationClassName
The scoping System's Creation class name.
SystemName
The scoping System's Name.
UnitModifier
The unit multiplier for the values returned by this Sensor.
UpperThresholdCritical
The Sensor's threshold values specify the ranges (min and max
values) for determining whether the Sensor is operating under Normal,
NonCritical, Critical or Fatal conditions. If the CurrentReading is
between UpperThresholdCritical and UpperThresholdFatal, then the
CurrentState is Critical.
UpperThresholdFatal
The Sensor's threshold values specify the ranges (min and max
values) for determining whether the Sensor is operating under Normal,
NonCritical, Critical or Fatal conditions. If the CurrentReading is above
UpperThresholdFatal, then the CurrentState is Fatal.
UpperThresholdNonCritical
The Sensor's threshold values specify the ranges (min and max
values) for determining whether the Sensor is operating under Normal,
NonCritical, Critical or Fatal conditions. If the CurrentReading is
between LowerThresholdNonCritical and UpperThresholdNonCritical,
then the Sensor is reporting a normal value. If the CurrentReading is
between UpperThresholdNonCritical and UpperThresholdCritical, then
the CurrentState is NonCritical.
Dell_VoltageSensor
Property Description
BaseUnits
The base unit of the values returned by this Sensor.
Possible values are:
• 0 = Unknown
• 1 = Other
• 2 = Degrees C
• 3 = Degrees F
• 4 = Degrees K
• 5 = Volts
312