Reference Guide
The Reference Guide contains the
file:///T|/htdocs/SOFTWARE/smcliins/cli81/en/refgd/index.html[10/19/2012 10:01:19 AM]
SystemCreationClassName The CreationClassName of the scoping system.
SystemName The System Name of the scoping system.
TransitioningToState
Indicates the target state to which the instance is transitioning.
Possible values are:
0 = Unknown
2 = Enabled
3 = Disabled
4 = Shut Down5 = No Change - Indicates that no transition is in progress.
6 = Offline
7 = Test
8 = Defer
9 = Quiesce
10 = Reboot
11 = Reset
12 = Not Applicable - Indicates the implementation does not support representing ongoing transitions.
A value other than 5 or 12 identifies the state to which the element is in the process of transitioning.
UniqueID A globally unique identifier for the Processor. This identifier can be unique only within a Processor Family.
UpgradeMethod
CPU socket information that includes data on how this Processor can be upgraded (if upgrades are supported). This property is an integer enumeration.
Possible values are:
1 = Other
2 = Unknown
3 = Daughter Board
4 = ZIF Socket
5 = Replacement/Piggy Back
6 = None
7 = LIF Socket
8 = Slot 1
9 = Slot 2
10 = 370 Pin Socket
11 = Slot A
12 = Slot M
13 = Socket 423
14 = Socket A (Socket 462)
15 = Socket 478
16 = Socket 754
17 = Socket 940
18 = Socket 939
19 = Socket mPGA604
20 = Socket LGA771
21 = Socket LGA775
22 = Socket S1
23 = Socket AM2
24 = Socket F (1207)
DCIM_NumericSensor
BaseUnits
The base unit of the values returned by this Sensor. All the values returned by this Sensor are represented in the units obtained by (BaseUnits * 10 raised to the power of the UnitModifier). For example, if BaseUnits is
Volts and the UnitModifier is -6, then the units of the values returned are MicroVolts. However, if the RateUnits property is set to a value other than "None", then the units are further qualified as rate units. In the above
example, if RateUnits is set to "Per Second", then the values returned by the Sensor are in MicroVolts/Second. The units apply to all numeric properties of the Sensor, unless explicitly overridden by the Units qualifier.
Possible values are:
0 = Unknown
1 = Other
2 = Degrees C
3 = Degrees F
4 = Degrees K
5 = Volts
6 = Amps
7 = Watts
8 = Joules
9 = Coulombs
10 = VA
11 = Nits
12 = Lumens
13 = Lux
14 = Candelas
15 = kPa
16 = PSI
17 = Newtons
18 = CFM
19 = RPM
20 = Hertz
21 = Seconds
22 = Minutes
23 = Hours
24 = Days
25 = Weeks
26 = Mils
27 = Inches
28 = Feet
29 = Cubic Inches
30 = Cubic Feet
31 = Meters
32 = Cubic Centimeters
33 = Cubic Meters
34 = Liters
35 = Fluid Ounces
36 = Radians
37 = Steradians