Reference Guide
The Reference Guide contains the
file:///T|/htdocs/SOFTWARE/smcliins/cli81/en/refgd/index.html[10/19/2012 10:01:19 AM]
WARNING_DEGRADED = 3
MINOR = 4
MAJOR = 5
CRITICAL = 6
FATAL_NONRECOVERABLE = 7
Note: Events with CRITICAL severity will cause OMCI to shut down the local system after a 60-second delay. The GlobalDisplaySeverityLevel property in the Dell_Configuration class should always be set to 6 or
below; otherwise, the system will not receive a shutdown command from OMCI.
The lowest WMI severity level that OMCI sends is WARNING_DEGRADED and the highest is CRITICAL. The severities of OMCI events are listed in
Table 2-1. OMCI sends local alerting and remote alerting for all the listed
events.
Table 2-1: Events Polled by OMCI
OMCI Event (Windows
Event Log Number)
Description
Severity Level Value
FanProbe
(1103)
A cooling device has exceeded a minor threshold. MINOR 4
DiskSizeIncreased
(2038)
The size of at least one hard drive has increased. WARNING_DEGRADED 3
DiskSizeDecreased
(2039)
The size of at least one hard drive has decreased. WARNING_DEGRADED 3
CurrentProbe
(1203)
An electrical current probe has exceeded a minor threshold. MINOR 4
DiskCapacity
(2034)
One of the hard drives is running out of free space.
In the current version, two user-defined thresholds are used. An event is generated only when the conditions of both thresholds are met. The first threshold,
expressed as an absolute value in megabytes, specifies the size of drives to be monitored. Drives with a capacity smaller than the specified size are ignored.
The second threshold is expressed as a percentage of the drive size. An event is generated when available free space on one of the monitored drives falls
below this percentage.
MINOR 4
EccMemory
(1403)
A memory checksum failure has occurred. MINOR 4
MemorySizeIncreased
(2032)
The memory size has been increased. WARNING_DEGRADED 3
MemorySizeDecreased
(2033)
The memory size has been decreased.
WARNING_DEGRADED 3
NumberOfDisksIncreased
(2031)
A hard drive has been added. WARNING_DEGRADED 3
NumberOfProcessorsDecreased
(2036)
A processor has been removed. WARNING_DEGRADED 3
Smart
(2037)
A hard drive condition has occurred that may eventually lead to a drive failure. MAJOR 5
ChassisIntrusion
(1253)
System Chassis Intrusion alert. WARNING_DEGRADED 3
TemperatureProbe
(1054)
A temperature probe has exceeded a critical threshold. CRITICAL 6
VoltageProbe
(1153)
A voltage probe has exceeded a minor threshold. MINOR 4
NumberOfProcessorsIncreased
(2035)
Number of processors on the system has increased WARNING_DEGRADED 3
Sample Scripts and BIOS Settings
WMI Sample Scripts
Getting BIOS Settings
Below is a sample VBScript to get the current list of BIOS Settings on a client system.
'********************************************************************************
'*** Name: SampleGetBBIOSSettings.vbs
'*** Purpose: To get the current list of BIOS Settings on a Dell OMCI 8.0 client.
'*** Usage: cscript.exe /nologo SampleGetBBIOSSettings.vbs <systemname>
'***
'*** This sample script is provided as an example only, and has not been
'*** tested, nor is warranted in any way by Dell; Dell disclaims any
'*** liability in connection therewith. Dell provides no technical
'*** support with regard to such scripting. For more information on WMI