Reference Guide
The Reference Guide contains the
file:///T|/htdocs/SOFTWARE/smcliins/cli81/en/refgd/index.html[10/19/2012 10:01:19 AM]
6 = System Management Module
7 = Motherboard
8 = Memory Module
9 = Processor Module
10 = Power Unit
11 = Add-in Card
LowerThresholdCritical
The Sensor's threshold values specify the ranges (min and max values) for determining whether the Sensor is operating under Normal, NonCritical, Critical or Fatal conditions. If the
CurrentReading is between LowerThresholdCritical and LowerThresholdFatal, then the CurrentState is Critical.
LowerThresholdFatal
The Sensor's threshold values specify the ranges (min and max values) for determining whether the Sensor is operating under Normal, NonCritical, Critical or Fatal conditions. If the
CurrentReading is below LowerThresholdFatal, then the CurrentState is Fatal.
LowerThresholdNonCritical
The Sensor's threshold values specify the ranges (min and max values) for determining whether the Sensor is operating under Normal, NonCritical, Critical or Fatal conditions. If
CurrentReading is between LowerThresholdNonCritical and UpperThresholdNonCritical, then the Sensor is reporting a normal value. If CurrentReading is between LowerThresholdNonCritical
and LowerThresholdCritical, then the CurrentState is NonCritical.
Name The Name property defines the label by which the object is known. When subclassed, the Name property can be overridden to be a Key property.
NominalReading NominalReading indicates the 'normal' or expected value for the NumericSensor.
RateUnits
Specifies if the units returned by this Sensor are rate units.
Possible Values are:
0 = None
1 = Per MicroSecond
2 = Per MilliSecond
3 = Per Second
4 = Per Minute
5 = Per Hour
6 = Per Day
7 = Per Week
8 = Per Month
9 = Per Year
SensorType
The Type of the Sensor.
Possible values are:
0 = Unknown
1 = Other
2 = Temperature
3 = Voltage
4 = Current
5 = Tachometer
6 = Counter
7 = Switch
8 = Lock
9 = Humidity
10 = Smoke Detection
11 = Presence
12 = Air Flow
Status
This property indicates the current status of the logical device.
Possible values are:
0 = OK
1 = Error
2 = Degraded
3 = Unknown
4 = Pred Fail
5 = Starting
6 = Stopping
7 = Service
8 = Stressed
9 = NonRecover
10 = No Contact
11 = Lost Comm
12 = Stopped
SystemCreationClassName The scoping System's Creation class name.
SystemName The scoping System's Name.
UnitModifier The unit multiplier for the values returned by this Sensor.
UpperThresholdCritical
The Sensor's threshold values specify the ranges (min and max values) for determining whether the Sensor is operating under Normal, NonCritical, Critical or Fatal conditions. If the
CurrentReading is between UpperThresholdCritical and UpperThresholdFatal, then the CurrentState is Critical.
UpperThresholdFatal
The Sensor's threshold values specify the ranges (min and max values) for determining whether the Sensor is operating under Normal, NonCritical, Critical or Fatal conditions. If the
CurrentReading is above UpperThresholdFatal, then the CurrentState is Fatal.
UpperThresholdNonCritical
The Sensor's threshold values specify the ranges (min and max values) for determining whether the Sensor is operating under Normal, NonCritical, Critical or Fatal conditions. If the
CurrentReading is between LowerThresholdNonCritical and UpperThresholdNonCritical, then the Sensor is reporting a normal value. If the CurrentReading is between
UpperThresholdNonCritical and UpperThresholdCritical, then the CurrentState is NonCritical.
CONFIGURATION
This section provides information about configuring boot device, hard disk drive sequence, password, internal speaker, power, and so on. Table 1-7 lists Dell OMCI Configuration classes and properties.
Table 1-7: Dell OpenManage Client Instrumentation Configuration Classes and Properties
Dell_BootDeviceSequence
BootDeviceName The name of this boot device as specified by the BIOS.
BootOrder The order of this device in the boot device priority list.
Possible values are: