44 = Ounce-Inches
45 = Gauss
46 = Gilberts
47 = Henries
48 = Farads
49 = Ohms
50 = Siemens
51 = Moles
52 = Becquerels
53 = PPM (parts/million)
54 = Decibels
55 = DbA
56 = DbC
57 = Grays
58 = Sieverts
59 = Color Temperature Degrees K
60 = Bits
61 = Bytes
62 = Words (data)
63 = DoubleWords
64 = QuadWords
65 = Percentage
Caption The caption of the device.
CreationClassName
Creation class name indicates the name of the class or the subclass used in the creation of an instance. When used with the other key properties of this class, this property allows all
instances of this class and its subclasses to be uniquely identified.
CurrentReading The current value indicated by the Sensor.
Description A short description of the device.
DeviceID An address or other identifying information to uniquely name the logical device.
Location Additional descriptive information about the temperature probe or probe's location.
LowerThresholdCritical
The Sensor's threshold values specify the ranges (min and max values) for determining whether the Sensor is operating under Normal, NonCritical, Critical or Fatal conditions. If the
CurrentReading is between LowerThresholdCritical and LowerThresholdFatal, then the CurrentState is Critical.
LowerThresholdFatal
The Sensor's threshold values specify the ranges (min and max values) for determining whether the Sensor is operating under Normal, NonCritical, Critical or Fatal conditions. If the
CurrentReading is below LowerThresholdFatal, then the CurrentState is Fatal.
LowerThresholdNonCritical
The Sensor's threshold values specify the ranges (min and max values) for determining whether the Sensor is operating under Normal, NonCritical, Critical or Fatal conditions. If
CurrentReading is between LowerThresholdNonCritical and UpperThresholdNonCritical, then the Sensor is reporting a normal value. If CurrentReading is between LowerThresholdNonCritical
and LowerThresholdCritical, then the CurrentState is NonCritical.
Name The Name property defines the label by which the object is known. When subclassed, the Name property can be overridden to be a Key property.
NominalReading NominalReading indicates the 'normal' or expected value for the NumericSensor.
RateUnits
Specifies if the units returned by this Sensor are rate units.
Possible values are:
0 = None
1 = Per MicroSecond
2 = Per MilliSecond
3 = Per Second
4 = Per Minute
5 = Per Hour
6 = Per Day
7 = Per Week
8 = Per Month
9 = Per Year
SensorType
The Type of the Sensor.
Possible values are:
0 = Unknown
1 = Other
2 = Temperature
3 = Voltage
4 = Current
5 = Tachometer
6 = Counter
7 = Switch
8 = Lock
9 = Humidity
10 = Smoke Detection
11 = Presence
12 = Air Flow
Status
This property indicates the current status of the logical device.
Possible values are:
0 = OK
1 = Error
2 = Degraded
3 = Unknown
4 = Pred Fail
5 = Starting
6 = Stopping
7 = Service
8 = Stressed
9 = NonRecover
10 = No Contact
11 = Lost Comm
12 = Stopped
SystemCreationClassName The scoping System's Creation class name.
SystemName The scoping System's Name.
UnitModifier The unit multiplier for the values returned by this Sensor.
UpperThresholdCritical
The Sensor's threshold values specify the ranges (min and max values) for determining whether the Sensor is operating under Normal, NonCritical, Critical or Fatal conditions. If the
CurrentReading is between UpperThresholdCritical and UpperThresholdFatal, then the CurrentState is Critical.