Reference Guide

Dell OpenManage Client Instrumentation Reference Guide
file:///T|/htdocs/SOFTWARE/smcliins/cli80/EN/refgd/index.htm[10/19/2012 9:56:27 AM]
BaseUnits
5 - Volts
6 - Amps
7 - Watts
8 - Joules
9 - Coulombs
10 - VA
11 - Nits
12 - Lumens
13 - Lux
14 - Candelas
15 - kPa
16 - PSI
17 - Newtons
18 - CFM
19 - RPM
20 - Hertz
21 - Seconds
22 - Minutes
23 - Hours
24 - Days
25 - Weeks
26 - Mils
27 - Inches
28 - Feet
29 - Cubic Inches
30 - Cubic Feet
31 - Meters
32 - Cubic Centimeters
33 - Cubic Meters
34 - Liters
35 - Fluid Ounces
36 - Radians
37 - Steradians
38 - Revolutions
39 - Cycles
40 - Gravities
41 - Ounces
42 - Pounds
43 - Foot-Pounds
44 - Ounce-Inches
45 - Gauss
46 - Gilberts
47 - Henries
48 - Farads
49 - Ohms
50 - Siemens
51 - Moles
52 - Becquerels
53 - PPM (parts/million)
54 - Decibels
55 - DbA
56 - DbC
57 - Grays
58 - Sieverts
59 - Color Temperature Degrees K
60 - Bits
61 - Bytes
62 - Words (data)
63 - DoubleWords
64 - QuadWords
65 - Percentage
Caption The caption of the device.
CreationClassName
Indicates the name of the class or the subclass used in the creation of an instance. When used with the other key properties of
this class, this property allows all instances of this class and its subclasses to be uniquely identified.
CurrentReading The current value indicated by the Sensor.
Description The current state indicated by the Sensor. This is always one of the "PossibleStates".
DeviceID An address or other identifying information to uniquely name the logical device.
Location
Identifies the physical location of the electrical current probe.
Possible values are:
1 - Other
2 - Unknown
3 - Processor
4 - Disk
5 - Peripheral Bay
6 - SMB Master
7 - Motherboard
8 - Memory Module
9 - Processor Module
10 - Power Unit
11 - Add-in Card
LowerThresholdCritical
The Sensor's threshold values specify the ranges (min and max values) for determining whether the Sensor is operating under
Normal, NonCritical, Critical or Fatal conditions. If the CurrentReading is between LowerThresholdCritical and
LowerThresholdFatal, then the CurrentState is Critical.
LowerThresholdFatal
The Sensor's threshold values specify the ranges (min and max values) for determining whether the Sensor is operating under
Normal, NonCritical, Critical or Fatal conditions. If the CurrentReading is below LowerThresholdFatal, then the CurrentState is
Fatal.
LowerThresholdNonCritical
The Sensor's threshold values specify the ranges (min and max values) for determining whether the Sensor is operating under
Normal, NonCritical, Critical or Fatal conditions. If CurrentReading is between LowerThresholdNonCritical and
UpperThresholdNonCritical, then the Sensor is reporting a normal value. If CurrentReading is between LowerThresholdNonCritical
and LowerThresholdCritical, then the CurrentState is NonCritical.
Name Defines the label by which the object is known. When subclassed, the Name property can be overridden to be a Key property.
NominalReading Indicates the 'normal' or expected value for the NumericSensor.
RateUnits
Specifies if the units returned by this Sensor are rate units.
Possible values are:
0 - None
1 - Per MicroSecond
2 - Per MilliSecond
3 - Per Second
4 - Per Minute
5 - Per Hour
6 - Per Day