Reference Guide

Dell OpenManage Client Instrumentation Reference Guide
file:///T|/htdocs/SOFTWARE/smcliins/cli78/en/refgd/index.htm[10/19/2012 10:04:25 AM]
22 = Minutes
23 = Hours
24 = Days
25 = Weeks
26 = Mils
27 = Inches
28 = Feet
29 = Cubic Inches
30 = Cubic Feet
31 = Meters
32 = Cubic Centimeters
33 = Cubic Meters
34 = Liters
35 = Fluid Ounces
36 = Radians
37 = Steradians
38 = Revolutions
39 = Cycles
40 = Gravities
41 = Ounces
42 = Pounds
43 = Foot-Pounds
44 = Ounce-Inches
45 = Gauss
46 = Gilberts
47 = Henries
48 = Farads
49 = Ohms
50 = Siemens
51 = Moles
52 = Becquerels
53 = PPM (parts/million)
54 = Decibels
55 = DbA
56 = DbC
57 = Grays
58 = Sieverts
59 = Color Temperature Degrees K
60 = Bits
61 = Bytes
62 = Words (data)
63 = DoubleWords
64 = QuadWords
65 = Percentage
Caption The caption of the device.
CreationClassName Creation class name indicates the name of the class or the subclass used in the creation of an instance. When used with the other key properties of this class, this property allows all instances of this class and
its subclasses to be uniquely identified.
CurrentReading The current value indicated by the Sensor.
Description The current state indicated by the Sensor. This is always one of the "PossibleStates".
DeviceID An address or other identifying information to uniquely name the logical device.
Location Identifies the physical location of the electrical current probe.
The following values are defined:
1 = Other
2 = Unknown
3 = Processor
4 = Disk
5 = Peripheral Bay
6 = SMB Master
7 = Motherboard
8 = Memory Module
9 = Processor Module
10 = Power Unit
11 = Add-in Card
LowerThresholdCritical The Sensor's threshold values specify the ranges (min and max values) for determining whether the Sensor is operating under Normal, NonCritical, Critical or Fatal conditions. If the CurrentReading is between
LowerThresholdCritical and LowerThresholdFatal, then the CurrentState is Critical.
LowerThresholdFatal The Sensor's threshold values specify the ranges (min and max values) for determining whether the Sensor is operating under Normal, NonCritical, Critical or Fatal conditions. If the CurrentReading is below
LowerThresholdFatal, then the CurrentState is Fatal.
LowerThresholdNonCritical The Sensor's threshold values specify the ranges (min and max values) for determining whether the Sensor is operating under Normal, NonCritical, Critical or Fatal conditions. If CurrentReading is between
LowerThresholdNonCritical and UpperThresholdNonCritical, then the Sensor is reporting a normal value. If CurrentReading is between LowerThresholdNonCritical and LowerThresholdCritical, then the
CurrentState is NonCritical.
MaxReadable MaxReadable indicates the largest value of the measured property that can be read by the NumericSensor.
MinReadable MinReadable indicates the smallest value of the measured property that can be read by the NumericSensor.
Name The Name property defines the label by which the object is known. When subclassed, the Name property can be overridden to be a Key property.
NominalReading NominalReading indicates the 'normal' or expected value for the NumericSensor.
NormalMax NormalMax provides guidance for the user as to the normal maximum range for the NumericSensor.
NormalMin NormalMin provides guidance for the user as to the normal minimum range for the NumericSensor.
RateUnits Specifies if the units returned by this Sensor are rate units.
The following values are defined:
0 = None
1 = Per MicroSecond
2 = Per MilliSecond
3 = Per Second
4 = Per Minute
5 = Per Hour