Reference Guide

--sysbatcharger
Valid Argument enable, disable
Description Enables or disables the battery charging system.
Example
C:\>cctk --sysbatcharger=enable
sysbatcharger=enable
--sysdefaults
Valid Argument reset
Description
Sets the behavior of the system after AC power is lost.
NOTE: Reboot the system on setting the value.
Example
C:\>cctk --sysdefaults=reset
sysdefaults=reset
--sysfanspeed
Valid Argument fullspeed, noisereduce
Description
Sets the system fan speed.
fullspeed — Sets the speed for normal cooling.
noisereduce — Sets the speed to slow to reduce noise.
Example
C:\>cctk --sysfanspeed=fullspeed
sysfanspeed=fullspeed
--sysid
Valid Argument Read-only
Description Defines the Dell Systems ID byte for systems that support it. The value of this feature is
-1, if the system does not support it.
Example
C:\>cctk --sysid
sysid=0169
--sysname
Valid Argument
Read-only
Description This function command reports the system identification string for a server, which is the
string displayed under the Dell logo during POST.
64