User's Manual

Serial Port Console Redirection 131
8
Serial Port Console Redirection
Serial Communication
For Dell PowerEdge x9xx, xx0x, and xx1x systems, serial console redirection
can be accomplished using COM1 or COM2.
Console Redirection Via COM1
To activate serial console redirection via COM1, you must configure the
following settings:
•Set
Serial Communication
Serial Communication
to
On with Console
Redirection via COM1
•Set
Serial Communication
External Serial Connector
to
COM1
Console Redirection Via COM2
Console Redirection via COM2 can be used to redirect either to the external
connector or to the remote access device, such as a BMC or DRAC 5/iDRAC6
Enterprise, for Serial Over LAN (SOL) communication.
To activate serial console redirection via COM2, you must configure the
following settings:
•Set
Serial Communication
Serial Communication
to
On with Console
Redirection via COM2
•Set
Serial Communication
External Serial Connector
to
COM2
NOTE: If the console redirection is used for SOL then the External Serial Connector
setting does not need to be configured.
When using COM2 for console redirection regardless of whether you redirect to
the external connector or for SOL, the BIOS reads the SOL baud rate from the
BMC and uses that setting to activate console redirection. SOL baud rate can
be configured using the Dell Deployment Toolkit, OMSA, DRAC, or the BMU.