User's Manual
102 Using the BMC Management Utility
Options for sensor
•
list
: Displays the complete list of sensors and thresholds in a wide table
format.
•
get <id>
: Displays information for sensors specified by the sensor ID
number.
Default Subcommand
If you do not specify a subcommand, this command is equivalent to the
sensor list command.
Options for mac
•
list
: Displays the number, MAC address, and status of all NICs. It also
displays the DRAC/iDRAC MAC address.
•
get <NIC number>
: Displays the MAC address and status of the
specified NIC number.
Default Subcommand
If you do not specify a subcommand, this command is equivalent to the mac
list command.
Options for lan
•
set <Mode>
: Sets the NIC selection mode. The selection modes are
Shared with LOM1, Shared with LOM2, Shared with LOM3, and Shared
with LOM4. If you are using iDRAC6 or iDRAC7 Enterprise, the
additional mode available is Dedicated.
•
set <Shared Failover Mode>
: Sets the shared failover mode to
one of the following options:
–Shared with LOM1
–Shared with LOM2
–Shared with LOM3
–Shared with LOM4
– Shared with Failover all LOMs
– Shared with Failover None.
•
get
: Displays the current NIC selection mode.