User's Manual
96 Using the BMC Management Utility
Default Subcommand
If a subcommand is not specified, this command functions the same as sel
info.
Options for sensor
•
list
— Displays the complete list of sensors and thresholds in a wide
table format.
•
get <
id
> ... [
<id>
]
— Displays information for sensors specified
by ID number.
•
thresh <
id
> <
threshold
> <
setting
>
— Allows you to set a
particular sensor threshold value. The sensor is specified by name. Valid
thresholds are:
•
unr
— Upper Non-Recoverable
•
ucr
— Upper Critical
•
unc
— Upper Non-Critical
•
lnc
— Lower Non-Critical
•
lcr
— Lower Critical
•
lnr
— Lower Non-Recoverable
Default Subcommand
If a subcommand is not specified, this command acts the same as sensor list.
IPMItool Command for Dynamic Entry on the DNS Server When DRAC is
Not Present
To create a dynamic entry on the DNS server when DRAC is not present, use
the following command:
ipmitool raw 0x18 0x58 0xe4 0x15
NOTE: You must enter a 21-byte hexadecimal number (a 8-byte input for the
PowerEdge 1435SC) for the DHCP name. If the DHCP name is less than 21 bytes (8
bytes for PowerEdge SC1435), pad the end with zeroes.