User's Manual
Configuring Your Managed System 33
Subnet Mask
The subnet mask for the static IP address.
NOTE: IP address 169.254.0.2 subnet mask 255.255.0.0 is
returned when the BMC is unable to contact the DHCP
server.
Default Gateway
The IP gateway for the static IP address.
VLAN Enable
Enables or disables the virtual LAN ID.
VLAN ID
This field is read-only when VLAN Enable is set to off.
To enter a value, navigate to the VLAN ID field from
another field.
A valid value for the virtual LAN ID must be a number
from 1 to 4094.
NOTE: If you enter a value outside the specified range,
either 1 or 4094 is entered, whichever is closest.
VLAN
This field is read-only when VLAN Enable is set to off.
Specifies the priority of the VLAN. The valid values
range from Priority 0 - Priority 7.
LAN Alert Enabled Enables or disables LAN alerting.
Alert Policy Entry 1 Enables or disables the first alert destination.
Alert Destination 1
This field is read-only when LAN Alert Enabled is
set to off.
Enter the IP address of the first alert destination. Use
the Left or Right arrow keys to navigate to each octet.
Use the numeric keypad to enter each octet.
The following IPv4 rules apply:
• IP addresses cannot be
127.xxx.xxx.xxx
, where
xxx
is
between
0-255
.
• The first octet must be between
1-223
(i.e.
143.xxx.xxx.xxx
)
• The last octet must not be
0
or
255
(i.e.
xxx.xxx.xxx.0
or
xxx.xxx.xxx.255
)
Table 2-1. Remote Access Configuration Utility (continued)
Option Description