User's Manual

BMC Management Utility Error Codes 109
First index larger than
total SEL records.
The first index is larger
than the total SEL
records.
A8h H/W or F/W
errors.
Unsupported
command.
Unsupported
operation.
0xC1
Sensor not present. Request sensor, data, or
record not present.
0xCB
Sensor command
error.
Command illegal for
specified sensor or
record type.
0xCD
Firmware error. Command response
could not be provided.
0xCE
Destination error. Cannot deliver request
to destination.
0xD3
Device error. Device specific (OEM)
errors.
0x01–0x
7E
A9h Processing
errors
(transient
errors that
may disappear
upon retry of
command).
BMC busy. BMC out of processing
resources.
0xC0
Destination timeout
error.
BMC timeout while
processing command
0xC3
BMC out of storage
space.
BMC out of storage
space required to
process command.
0xC4
Invalid reservation ID. Invalid reservation ID. 0xC5
Duplicate command. Cannot execute
duplicated request.
0xCF
Table A-1. BMC Management Utility Error Codes (continued)
Code Classification Message Description IPMI
Error