Users Guide

52 Using the BMC Management Utility
Specifies the sensor group (temp, volt, fan, discrete, or numeric) for which information is displayed. If
you do not specify a sensor group, all sensors for which there is information will be displayed.
-format <oemlist|legacy>
Use different formats to output the sensor data. Default format is oemlist. Legacy format is diplayed as below:
Sensor Name | Sensor Type | Sensor # | Status [| Value | Units ]
Subcommands
[temp | fan | volt | discrete | numeric]
Specifies the sensor group for which information is displayed. If no sensor group is specified, information
is displayed for all groups.
Figure 3-12. Sensor option example
connect
Synopsis
connect -ip bmc-ip-address | bmc-host-name [-u username] [-p password]
[-k IPMI encryption key value]
connect -com bmc_ip_address | bmc_hostname -u username -p password
[-k KG value]
<command>
Description
This command establishes an IPMI connection with the remote server in the interactive mode to enable
the user to perform server management activities. The command remains active until the user quits the
command prompt or uses the command again to connect to a different server.