Reference Guide

The neighbor does not inherit the global BFD disable values configured with the bfd all-
neighbors command or configured for the peer group to which the neighbor belongs.
The neighbor only inherits the global timer values configured with the bfd all-neighbors
command: interval, min_rx, and multiplier.
When you remove the Disabled state of a BFD for a BGP session with a specified neighbor by entering the
no neighbor bfd disable command, the BGP link with the neighbor returns to normal operation
and uses the BFD session parameters globally configured with the bfd all-neighbors command or
configured for the peer group to which the neighbor belongs.
Related
Commands
show bfd neighbors displays the BFD neighbor information on all interfaces or a specified interface.
show bfd neighbors
Display BFD neighbor information on all interfaces or a specified interface.
Z9500
Syntax
show bfd neighbors interface [detail]
Parameters
interface
Enter one of the following keywords and slot/port or number information:
For a 10-Gigabit Ethernet interface, enter the keyword
TenGigabitEthernet then the slot/port information.
For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the
slot/port information.
For a port channel interface, enter the keywords port-channel then a
number. The range is from 1 to 512.
For a VLAN interface, enter the keyword vlan then a number from 1 to 4094.
detail (OPTIONAL) Enter the keyword detail to view detailed information about BFD
neighbors.
Defaults none
Command Modes
EXEC
EXEC Privilege
Command
History
This guide is platform-specific. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.0.0.0 Introduced on the Z9000.
8.3.19.0 Introduced on the S4820T.
8.3.8.0 Added support for BFD for BGP on the S4810.
8.4.1.3 Added support for BFD for BGP on the E-Series ExaScale.
8.2.1.0 Introduced on the E-Series ExaScale.
7.6.1.0 Introduced on the C-Series.
7.5.1.0 Added support for BFD for VLAN and port-channel interfaces on the E-Series.
7.4.1.0 Introduced BFD on physical ports on the E-Series.
Bidirectional Forwarding Detection (BFD) 259