Reference Guide
Command
History
This guide is platform-specific. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.7(0.0) Introduced on the S6000-ON.
9.7(0.0) Introduced on the S-Series, Z-Series, and MXL switch.
Usage
Information
When you enable ingress sFlow on an interface, flow sampling is done on any incoming traffic.
NOTE: After a physical port is a member of a LAG, it inherits the sFlow configuration from the LAG
port.
Related
Commands
sflow enable (Global) — turns sFlow globally.
sflow extended-switch enable
Enable packing information on a switch only.
Z9500
Syntax
sflow extended-switch enable
To disable packing information, use the no sflow extended-switch [enable] command.
Parameters
enable Enter the keyword enable to enable global extended information.
Defaults Disabled.
Command Modes CONFIGURATION
Command
History
This guide is platform-specific. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.2(1.0) Introduced on the Z9500.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
8.2.1.0 Introduced on S-Series Stacking.
8.1.1.0 Introduced on the E-Series ExaScale.
7.7.1.0 Introduced on the S-Series.
7.6.1.0 Introduced on the C-Series.
7.4.1.0 Introduced on the E-Series.
Usage
Information
Dell Networking OS version 7.8.1.0 and later enhances the sflow implementation for real time traffic
analysis on the E-Series to provide extended gateway information in cases where the destination IP
addresses are learned by different routing protocols and for cases where the destination is reachable over
ECMP.
Related
Commands
show sflow — displays the sFlow configuration.
sFlow 1279