Reference Guide
Version Description
8.3.7.0 Introduced on the S4810.
8.2.1.0 Introduced on the C-Series, E-Series TeraScale, and E-Series ExaScale. Maximum
rate limit on E-Series reduced from 4000 to 3000.
7.4.1.0 Introduced
Example
Dell#
Dell#conf
Dell(conf)#protocol-tunnel rate-limit 1000
Dell(conf)#
Related
Commands
show protocol-tunnel — displays tunneling information for all VLANs.
show running-config — displays the current configuration.
show protocol-tunnel
Display protocol tunnel information for all or a specified VLAN-Stack VLAN.
Z9500
Syntax
show protocol-tunnel [vlan vlan-id]
Parameters
vlan
vlan-id
(OPTIONAL) Enter the keyword vlan then the VLAN ID to display information for
the one VLAN. The range is from 1 to 4094.
Defaults none
Command Modes EXEC
Command
History
This guide is platform-specific. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.2(1.0) Introduced on the Z9500.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
8.2.1.0 Introduced on the C-Series, E-Series and E-Series ExaScale.
7.4.1.0 Introduced
Example
Dell#show protocol-tunnel
System Rate-Limit: 75 frames/second
VLAN Protocols Interface
1000 STP,PVST Te 1/7,Te 1/6
1001 LLDP,GVRP Te 1/7,Te 1/6
1002 MMRP,MVRP Te 1/7,Te 1/6
1003 LACP,DOT1X Te 1/7,Te 1/6
1004 OAM,PAUSE Te 1/7,Te 1/6
1005 E-LMI Te 1/7,Te 1/6
1274 Service Provider Bridging