Reference Guide

show alarms
View alarms for the system Core, switching core, port modules, fan trays, and power supplies.
Z9500
Syntax
show alarms [threshold]
Parameters
threshold (OPTIONAL) Enter the keyword threshold to display the temperature thresholds
set for the line cards, RPM, and SFMs.
Command Modes
EXEC
EXEC Privilege
Command
History
This guide is platform-specific. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.2(1.0) Introduced on the Z9500.
8.3.19.0 Introduced on the S4820T.
8.3.12.0 Introduced on the S4810.
8.3.11.1 Introduced on the Z9000.
8.1.1.0 Introduced on the E-Series ExaScale.
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
E-Series Original command.
Examples
Dell#show alarms
-- Minor Alarms --
Alarm Type Duration
---------------------------------------------------------------------------
No minor alarms
-- Major Alarms --
Alarm Type Duration
---------------------------------------------------------------------------
PEM 0 in unit 0 down 25 sec
PEM 2 in unit 0 down 6 sec
Dell#show alarms threshold
-- System Core --
-- Temperature Limits (deg C) --
---------------------------------------------------------------------------
Minor Minor Off Major Major Off Shutdown
S0 50 45 50 45 N/A
S1 N/A N/A N/A N/A N/A
S2 50 45 50 45 N/A
S3 50 45 50 45 N/A
S4 40 35 40 35 N/A
S5 50 45 50 45 N/A
S6 67 62 67 62 N/A
S7 68 63 68 63 N/A
S8 66 61 66 61 N/A
S9 66 61 66 61 N/A
102