Command Line Reference Guide
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.2(1.0) Introduced on the Z9500.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
8.3.1.0 Introduced the verbose option.
7.7.1.0 Introduced on the S-Series.
Usage
Information
Use the show diag information command to view the progress of offline
diagnostics on Z9500 CPUs: line-card processors (Linecard slots 0 to 2), Control
Processor (Linecard slot 3), and Route Processor (Linecard slot 4).
Example:
Before offline
diagnostics are
run on a switch
Dell# show diag information
Diag information:
Diag software image version:
9.5(0.1)
----------------------------
Linecard slot 0: No card diags executed yet (Card
Offline).
Linecard slot 1: No card diags executed yet (Card
Offline).
Linecard slot 2: No card diags executed yet (Card
Offline).
Linecard slot 3: No card diags executed yet (Card
Offline).
----------------------------
Example: After
offline
diagnostics are
run on a switch
Dell# show diag information
Diag information:
Diag software image version:
9.5(0.1)
----------------------------
Linecard slot 0: Card diags are done (Card Offline).
Linecard slot 1: Card diags are done (Card Offline).
Linecard slot 2: Card diags are done (Card Offline).
Linecard slot 3: Card diags are done (Card Offline).
----------------------------
show diag testcase
Display the offline diagnostic tests available for the Z9500 CPUs at each level.
Z9500
Syntax
show diag testcase {all | {{cp | rp | linecard} unit-id}
[alllevels | level0 | level1 | level2]
Parameters
all Enter the keyword all to display the complete suite of
offline diagnostic tests available on the Z9500.
Debugging and Diagnostics
573