Command Line Reference Guide

ERROR: Qsfp Module:20 is not present
ERROR: Qsfp Module:21 is not present
ERROR: Qsfp Module:22 is not present
ERROR: Qsfp Module:23 is not present
ERROR: Qsfp Module:24 is not present
ERROR: Qsfp Module:27 is not present
ERROR: Qsfp Module:28 is not present
ERROR: Qsfp Module:29 is not present
qsfpOpticsTest ..............................................
FAIL
qsfpPhyTest .................................................
PASS
rtcTest .....................................................
PASS
sataSsdTest .................................................
PASS
Starting test: temperatureTest ......
Thermal Monitor Diodes:
Diode[0] temperature 38.0 C
Diode[1] temperature 39.4 C
Diode[2] temperature 39.1 C
Diode[4] temperature 38.9 C
Port card[0]:
Average temperature 50.2 C, maximum 53.6 C
Port card[1]:
Average temperature 48.7 C, maximum 51.4 C
Port card[2]:
Average temperature 48.8 C, maximum 50.9 C
Ethernet MAC temperature 50.0 C
temperatureTest .............................................
PASS
--------- Group Test Statistics ---------
Total : 11
Passed : 9
Failed : 2
Elapsed time : 00H:00M:18S
Stop reason : after completion
------ Failed tests (level, times) ------
i2cTest (0, 1)
qsfpOpticsTest (0, 1)
show diag information
Display the status of offline diagnostic tests on a switch.
Z9500
Syntax
show diag information
Defaults None.
Command
Modes
EXEC Privilege
Command
History
This guide is platform-specific. For command information about other platforms,
refer to the relevant Dell Networking OS Command Line Reference Guide.