Command Line Reference Guide

11
Debugging and Diagnostics
Use the debugging and diagnostics commands described in this chapter to troubleshoot switch
operation.
This chapter contains the following sections:
Offline Diagnostic Commands
Buffer Tuning Commands
Hardware Commands
Offline Diagnostic Commands
Use the offline diagnostics test suite to isolate faults and debug switch hardware. While tests are running,
the system results are saved as a text file in the flash directory: TestReport-
N.txt , where N is 0,1, or 2 for
the line-card processor (LP) and 0 for the Control processor (CP) and Route Processor (RP). To display
the system results in this text file, use the
show file command.
Important Points to Remember
Offline diagnostics can only be run when the unit is offline.
You can only run offline diagnostics on a unit to which you are connected via the console. In other
words, you cannot run diagnostics on a unit to which you are connected to via a stacking link.
Diagnostic results are printed to the screen. The Dell Networking OS does not write them to memory.
Diagnostics only test connectivity, not the entire data path.
diag
Run offline diagnostics on all CPUs or on a specified CPU in the switch.
Z9500
Syntax
diag {all | {{cp | rp | linecard} unit-id} [alllevels | level0
| level1 | level2] [interactive] [testname name] [terminate]
Parameters
all Enter the keyword all to run offline diagnostic tests on all
Z9500 CPUs, including the Control Processor, Route
Processor, and line cards.
cp unit-id Enter the cp unit-id parameters to run offline diagnostic
tests only on the Control Processor CPU. The Control
Processor CPU ID is 0.
564
Debugging and Diagnostics