Command Line Reference Guide

Command
History
This guide is platform-specific. For command information about other platforms,
refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.2(1.0) Introduced on the Z9500.
8.3.19.0 Introduced on the S4820T.
8.3.11.4 The brief parameter no longer displays the current Reload
mode. To display Reload mode, use the show reload-
type
command. Modified the show system stack-unit
command output to support Piece Part ID (PPID).
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
7.8.1.0 The Boot Flash field displays the code level for boot code
2.8.1.1 and newer, while older boot codes display as
"Present".
7.7.1.0 Added Master Priority field.
7.6.1.0 Introduced on the S-Series.
Example
Dell#show system brief
System MAC : 74:86:7a:ff:6f:06
Reload-Type: normal-reload [Next boot : normal-reload]
-- Line Card Info --
Linecard UnitType Status ReqTyp CurTyp Version Ports
---------------------------------------------------------------
0 Linecard online Z9500LC36 Z9500LC36 9-5 144
1 Linecard online Z9500LC48 Z9500LC48 9-5 192
2 Linecard online Z9500LC48 Z9500LC48 9-5 192
-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed(rpm) Power Usage
(W)
---------------------------------------------------------------
---
0 0 absent
0 1 absent
0 2 absent
0 3 absent
Total power: 0.0 W
-- Fan Status --
Unit Bay TrayStatus Fan0 Speed Fan1 Speed
--------------------------------------------------
0 down
1 down
2 down
3 absent
4 down
160
Control and Monitoring