Command Line Reference Guide

Version Description
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
6.5.1.0 Introduced on the E-Series.
Usage
Information
On an MSTP switch, a port configured as an edge port immediately transitions to
the Forwarding state. Only configure ports connected to end-hosts as edge ports.
Consider an edge port similar to a port with spanning-tree portfast enabled.
If you do not enable shutdown-on-violation, BPDUs are still sent to the RPM
CPU.
tc-flush-standard
Enable the MAC address flushing after receiving every topology change notification.
Z9500
Syntax
tc-flush-standard
To disable, use the no tc-flush-standard command.
Defaults Disabled.
Command
Modes
CONFIGURATION
Command
History
This guide is platform-specific. For command information about other platforms,
refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.2(1.0) Introduced on the Z9500.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
6.5.1.0 Introduced
Usage
Information
By default, the system implements an optimized flush mechanism for MSTP. This
mechanism helps in flushing the MAC addresses only when necessary (and less
often) allowing for faster convergence during topology changes. However, if a
Multiple Spanning Tree Protocol (MSTP)
1109