Install Guide

LED behaviors
Figure 4. VEP4600 LEDs
1. Power LED 2. Primary unit indicator LED
3. System LED 4. Locator LED
5. Temperature LED 6. Fan LED
7. SFP+ indicator LED 8. 10/100/1000 BaseT RJ-45 networking link (left) and activity
(right) LEDs
9. 10/100/1000 BaseT RJ-45 networking link (left) and activity
(right) LEDs for the processor (left) and for the BMC
(right)
Table 1. VEP4600 LED behavior (continued)
LED Description
System Status/Health LED
Offsystem off or in standby
Solid greenNormal operation
Flashing greenBooting
Solid yellow (amber)Critical system error or CPU power
off.
Flashing yellowNoncritical system error, fan failure, or
power supply failure
Power LED
Offsystem off or in standby
Solid GreenNormal operation
Solid yellowPOST is in process
Flashing yellowPower supply failed
Primary unit indicator LED
Solid greenThe system is in Stand-alone mode
OffThe systems in standby mode
FAN LED
Offsystem off or in standby
Solid greenNormal operation; fan powered and running
at the expected RPM
Solid yellowFan failed
PSU LED
OffNo power
Solid greenNormal operation or standby mode
Solid yellowPower supply critical event causing a
shutdown
VEP4600 platform 9