Users Guide
Table Of Contents
- Dell EMC VEP4600 BMC User Guide
- About this guide
- New in this release
- Hardware and software support
- BMC web GUI
- Configuration methods
- Current released firmware
- Remote power cycle system
- Access system health sensors
- Access FRU data
- ipmiutil package
- Dell EMC support
Access system health sensors
To check sensor information, use the following command:
root@dellemc-diag-os:~# ipmitool sensor list
To change the sensor threshold, see the IPMI Specification v2.0 chapter 35.8 Set Sensor Thresholds Command.
● Request data byte 1—Sensor number, FFH=reserved
● Request data byte 2—
○ [7:6] - reserved. Write as 00b
○ [5] - 1b=set upper non-recoverable threshold
○ [4] - 1b=set upper critical threshold
○ [3] - 1b=set upper non-critical threshold
○ [2] - 1b=set lower non-recoverable threshold
○ [1] - 1b=set lower critical threshold
○ [0] - 1b=set lower non-critical threshold
● Request data byte 3—lower non-critical threshold. Ignored if bit 0 of byte 2 = 0
● Request data byte 4—lower critical threshold. Ignored if bit 1 of byte 2 = 0
● Request data byte 5—lower non-recoverable threshold. Ignored if bit 2 of byte 2 = 0
● Request data byte 6—upper non-critical threshold. Ignored if bit 3 of byte 2 = 0
● Request data byte 7—upper critical threshold value. Ignored if bit 4 of byte 2 = 0
● Request data byte 8—upper non-recoverable threshold value. Ignored if bit 5 of byte 2 = 0
● Response data byte 1—Completion code
ipmitool sensors
-root@dellemc-diag-os:~# ipmitool sensor list
PSU1_Status | 0x0 | discrete | 0x0980| na | na | na |
na | na | na
PSU2_Status | 0x0 | discrete | 0x0180| na | na | na |
na | na | na
AC_Status | 0x0 | discrete | 0x0080| na | na | na |
na | na | na
Watchdog2 | 0x0 | discrete | 0x0080| na | na | na |
na | na | na
SEL | 0x0 | discrete | 0x0080| na | na | na |
na | na | na
Power_Status | 0x0 | discrete | 0x0180| na | na | na |
na | na | na
Fan1_Status | 0x0 | discrete | 0x0180| na | na | na |
na | na | na
Fan2_Status | 0x0 | discrete | 0x0180| na | na | na |
na | na | na
Fan3_Status | 0x0 | discrete | 0x0180| na | na | na |
na | na | na
Fan4_Status | 0x0 | discrete | 0x0180| na | na | na |
na | na | na
Fan5_Status | 0x0 | discrete | 0x0180| na | na | na |
na | na | na
CPU_Temp | 41.000 | degrees C | ok | na | na | na |
92.000 | 93.000 | na
DIMM1_Temp | 33.000 | degrees C | ok | na | na | na |
92.000 | 95.000 | na
DIMM2_Temp | 32.000 | degrees C | ok | na | na | na |
92.000 | 95.000 | na
DIMM3_Temp | na | | na | na | na | na |
na | na | na
8
84 Access system health sensors