White Papers
Stacking and VLT
Dell EMC Technical White Paper
StandbyUnit#stack-unit 1 renumber 2
Renumbering management unit will reload the stack.
Warning: Interface configuration for current unit will be lost!
Proceed[confirm yes/no]:yes
StandbyUnit#conf t
StandbyUnit(conf)#stack-unit 2 priority 4
MasterUnit(conf)#stack-unit 1 priority 10
The stacking units can be connected while they are powered up or down. When a switch is added to a stack,
the management unit performs a system check on the new unit to ensure that the hardware type is compatible.
Similarly, a check is performed on the Dell Networking Operating System Version.
The following is the sample configuration on one of the units:
MasterUnit(conf)#stack-unit 1 stack-group 1
MasterUnit(conf)#Mar 29 01:58:00: %STKUNIT1-M:CP %IFMGR-6-STACK_PORTS_ADDED: Ports Te 1/5
Te 1/6 Te 1/7 Te 1/8 have been configured as stacking ports. Please save and reset
stack-unit 1 for config to take effect
MasterUnit(conf)#exit
MasterUnit#Mar 29 01:58:48: %STKUNIT1-M:CP %SYS-5-CONFIG_I: Configured from console
MasterUnit#write memory
!
Mar 29 01:58:56: %STKUNIT1-M:CP %FILEMGR-5-FILESAVED: Copied running-config to startup-
config in flash by default
MasterUnit#reload
The configuration looks as follows after it has been applied on both switches:
MasterUnit>Show System
Stack MAC : e4:f0:04:3f:b9:15
Reload-Type : normal-reload [Next boot : normal-reload]
-- Unit 1 --
Unit Type : Management Unit
Status : online
Next Boot : online
Required Type : S4048-ON - 54-port TE/FG (SK-ON)
Current Type : S4048-ON - 54-port TE/FG (SK-ON)
Master priority : 10
Hardware Rev : 2.0
Num Ports : 72
Up Time : 6 min, 4 sec
Dell Networking OS Version : 9.10(0.1)
Jumbo Capable : yes
POE Capable : no
FIPS Mode : disabled
Burned In MAC : e4:f0:04:3f:b9:15
No Of MACs : 3
[Output Omitted]
-- Unit 2 --
Unit Type : Standby Unit
Status : online
Next Boot : online
Required Type : S4048-ON - 54-port TE/FG (SK-ON)
Current Type : S4048-ON - 54-port TE/FG (SK-ON)
Master priority : 4
Hardware Rev : 2.0
Num Ports : 72
Up Time : 6 min, 1 sec
Dell Networking OS Version : 9.10(0.1)