Command Line Reference Guide
Field Description
Status Operational status of the link between a server CNA port and a SAN
fabric: Logged In - Server has logged in to the fabric and is able to
transmit FCoE traffic.
Example
FTOS# show npiv devices brief
Total NPIV Devices = 2
---------------------------------------------------------------
----------------------------
ENode-Intf ENode-WWPN FCoE-Vlan Fabric-Intf
Fabric-Map LoginMethod Status
---------------------------------------------------------------
---------------------------
Te 0/12 20:01:00:10:18:f1:94:20 1003 Fc 0/5
fid_1003 FLOGI LOGGED_IN
Te 0/13 10:00:00:00:c9:d9:9c:cb 1003 Fc 0/0
fid_1003 FDISC LOGGED_IN
Usage
Information
The following table describes the show npiv devices output shown in the example
below.
Field Description
ENode [
number
] A server CNA that has successfully logged in to a fabric over an
S5000 Ethernet port in ENode mode.
Enode MAC MAC address of a server CNA port.
Enode Intf Port number of a server-facing Ethernet port operating in ENode
mode.
FCF MAC Fibre Channel forwarder MAC: MAC address of S5000 FCF interface.
Fabric Intf Fabric-facing Fibre Channel port (
slot/port
) on which FCoE traffic is
transmitted to the specified fabric.
FCoE VLAN ID of the dedicated VLAN used to transmit FCoE traffic from a server
CNA to a fabric and configured on both the server-facing S5000 port
and server CNA port.
Fabric Map Name of the FCoE map containing the FCoE/FC configuration
parameters for the server CNA-fabric connection.
Enode WWPN Worldwide port name of the server CNA port.
Enode WWNN Worldwide node name of the server CNA.
FCoE MAC Fabric-provided MAC address (FPMA). The FPMA consists of the FC-
MAP value in the FCoE map and the FC-ID provided by the fabric
after a successful FLOGI. In the FPMA, the most significant bytes are
the FC-MAP; the least significant bytes are the FC-ID.
FC-ID FC port ID provided by the fabric.