Command Line Reference Guide
An FCoE map is used to identify the SAN fabric to which FCoE storage traffic is sent and to
virtualize S5000 FC ports so that they appear to downstream server CNA ports as FCoE
Forwarder (FCF) ports on an FCoE network.
The following table describes the show fcoe-map brief and show fcoe-map map-
name output shown in the examples below.
Field Description
Fabric-Name Name of a SAN fabric.
Fabric ID The ID number of the SAN fabric to which FC traffic is forwarded.
VLAN ID The dedicated FCoE VLAN used to transport FCoE storage traffic
between servers and a fabric over the NPIV proxy gateway. The
configured VLAN ID must be the same as the fabric ID.
VLAN priority FCoE traffic uses VLAN priority 3. (This setting is not user-
configurable.)
FC-MAP FCoE MAC address-prefix value - The unique 24-bit MAC address
prefix that identifies a fabric.
FKA-ADV-period Time interval (in seconds) used to transmit FIP keepalive
advertisements.
FCF Priority The priority used by a server to select an upstream FCoE forwarder.
Config-State Indicates whether the configured FCoE and FC parameters in the
FCoE map are valid: Active (all mandatory FCoE and FC parameters
are correctly configured) or Incomplete (either the FC-MAP value,
fabric ID, or VLAN ID are not correctly configured).
Oper-State Operational status of link to the fabric: Up (link is up and transmitting
FC traffic), Down (link is down and not transmitting FC traffic), Link-
wait (link is up and waiting for FLOGI to complete on peer FC port), or
Removed (port has been shut down).
Members S5000 Ethernet and FC ports that are members of the dedicated FCoE
VLAN that carries storage traffic to the specified fabric.
Example
FTOS# show fcoe-map brief
Fabric Fabric Vlan FC-MAP FCF Active State
Name ID ID Priority
Fabric1 1 1002 0x0EFC00 128 Y Up (at least 1 FC
port is up)
Fabric2 2 1003 0x0EFC01 128 Y Down
Fabric3 2 1004 0x0EFC02 128 N Down
FTOS# show fcoe-map fabric1
Fabric Name FABRIC_NAME_1
Fabric id 1002
Vlan id 1002
Vlan priority 3
FC-MAP 0x0EFC00
FKA-ADV-period 8000ms
Operational-Mode Up
Members
TE0/1 TE0/2 FC0/1 FC0/2 FC0/3 FC0/4
902