Command Line Reference Guide
Related
Commands
• fefd – enables far-end failure detection.
show fefd
View FEFD status globally or on a specific interface.
S5000
Syntax
show fefd [interface-type slot/port]
Parameters
interface-type
slot/port
(OPTIONAL) Enter one of the following keywords and slot/port or
number information. Valid slot numbers are 0-11. The valid port
numbers for each interface type are listed below.
• For a 10-Gigabit Ethernet interface, enter the keyword
tengigabitethernet followed by slot/port numbers.
The port range is 0 to 63.
• For a 40-Gigabit Ethernet interface, enter the keyword
fortyGigE followed by slot/port numbers. The ports are 48,
52, 56, and 60.
Command Modes
• EXEC
• EXEC Privilege
Command History
Version 9.0(1.3) Introduced on the S5000.
Usage
Information
The following describes the show fefd command shown in the Example below.
Field Description
Interface Displays the interfaces type and number.
Mode Displays the mode (aggressive or normal) or NA if the interface
contains fefd reset in its configuration.
Interval Displays the interval between FEFD packets.
State Displays the state of the interface and can be one of the following:
• bi-directional (interface is up and connected and ing
neighbor’s echoes).
• err-disabled (only found when the FEFD mode is aggressive
and when the interface has not n its neighbor’s echoes for 3
times the message interval. To reset an interface in this state,
use the fefd reset command.)
• unknown (only found when FEFD mode is normal.
• locally disabled (interface contains the fefd reset
command in its configuration).
835