Command Line Reference Guide

monitor (OPTIONAL) Enter the keyword monitor to monitor traffic on the
monitoring interface specified in the flow-based monitoring session
along with the filter operation.
Defaults Not configured.
Command Modes ACCESS-LIST
Command History
Version 9.0(1.3) Introduced on the S5000.
Usage
Information
Most ACL rules require one entry in the CAM. However, rules with TCP and UDP port operators
(gt, lt, range) may require more than one entry. The range of ports is configured in the CAM
based on bitmask boundaries; the space required depends on exactly what ports are included
in the range.
Example
An ACL rule with a TCP port range of 4000 - 8000 uses eight entries in the CAM:
Rule# Data Mask From To #Covered
1 0000111110100000 1111111111100000 4000 4031 32
2 0000111111000000 1111111111000000 4032 4095 64
3 0001000000000000 1111100000000000 4096 6143 2048
4 0001100000000000 1111110000000000 6144 7167 1024
5 0001110000000000 1111111000000000 7168 7679 512
6 0001111000000000 1111111100000000 7680 7935 256
7 0001111100000000 1111111111000000 7936 7999 64
8 0001111101000000 1111111111111111 8000 8000 1
Total Ports: 4001
Example
An ACL rule with TCP port lt 1023 takes only one entry in the CAM:
Rule# Data Mask From To #Covered
1 0000000000000000 1111110000000000 0 1023 1024
Total Ports: 1024
Related
Commands
deny – assigns a filter to deny IP traffic.
deny udp – assigns a filter to deny UDP traffic.
deny udp
Configure a filter to drop user datagram protocol (UDP) packets meeting the filter criteria.
S5000
Syntax
deny udp {source address mask | any | host ipv6-address}
[operator port [port]] {destination address | any | host ipv6-
address} [operator port [port]] [count [byte]] | [monitor]
To remove this filter, you have two choices:
610