Command Line Reference Guide

SFP 1 RX Power Low Warning threshold = 0.016mW
===================================
SFP 1 Temperature = 39.930C
SFP 1 Voltage = 3.293V
SFP 1 Tx Bias Current = 6.894mA
SFP 1 Tx Power = 0.328mW
SFP 1 Rx Power = 0.000mW
===================================
SFP 1 Data Ready state Bar = False
SFP 1 Rx LOS state = True
SFP 1 Tx Fault state = False
SFP 1 Rate Select state = False
SFP 1 RS state = False
SFP 1 Tx Disable state = False
===================================
SFP 1 Temperature High Alarm Flag = False
SFP 1 Voltage High Alarm Flag = False
SFP 1 Tx Bias High Alarm Flag = False
SFP 1 Tx Power High Alarm Flag = False
SFP 1 Rx Power High Alarm Flag = False
SFP 1 Temperature Low Alarm Flag = False
SFP 1 Voltage Low Alarm Flag = False
SFP 1 Tx Bias Low Alarm Flag = False
SFP 1 Tx Power Low Alarm Flag = False
SFP 1 Rx Power Low Alarm Flag = True
===================================
!-------output truncated -------------------------!
Related
Commands
interface – configures a physical interface on the switch.
show ip interface – displays Layer 3 information about the interfaces.
show interfaces – displays information on a specific physical interface or virtual interface.
show inventory – displays the S5000 switch components (including media), FTOS version
including hardware identification numbers, and configured protocols.
show range
Display all interfaces configured using the interface range command.
S5000
Syntax
show range
Command Modes INTERFACE RANGE (config-if-range)
Command History
Version 9.0(1.3) Introduced on the S5000.
Example
FTOS(conf-if-range-so-2/0-1,fa-0/0)#show range
interface tengigabitethernet 2/0 - 1
interface tengigabitethernet 0/0
FTOS(conf-if-range-so-2/0-1,fa-0/0)#