Command Line Reference Guide

Field Description
Temp Low Warning threshold Factory-defined setting. Value can differ between
SFP and SFP+.
Voltage Low Warning threshold Factory-defined setting. Value can differ between
SFP and SFP+.
Bias Low Warning threshold Factory-defined setting. Value can differ between
SFP and SFP+.
TX Power Low Warning threshold Factory-defined setting. Value can differ between
SFP and SFP+.
Power Low Warning threshold Factory-defined setting. Value can differ between
SFP and SFP+.
Temperature Current temperature of the SFPs. If this temperature
crosses Temp High alarm/warning thresholds, the
temperature high alarm/warning flag is set to true.
Voltage Current voltage of the SFPs. If this voltage crosses
voltage high alarm/warning thresholds, the voltage
high alarm/warning flag is set to true.
Tx Bias Current Present Tx bias current of the SFP. If this crosses
bias high alarm/warning thresholds, the Tx bias high
alarm/warning flag is set to true. If it falls below the
low alarm/warning thresholds, the Tx bias low alarm/
warning flag is set to true.
Tx Power Present Tx power of the SFP. If this crosses Tx power
alarm/warning thresholds, the Tx power high alarm/
warning flag is set to true. If it falls below the low
alarm/warning thresholds, the Tx power low alarm/
warning flag is set to true.
Rx Power Present Rx power of the SFP. This value is either
average Rx power or OMA. This depends on the Rx
Power measurement type displayed above. If this
crosses Rx power alarm/warning thresholds, the Rx
power high alarm/warning flag is set to true. If it falls
below the low alarm/warning thresholds, the Rx
power low alarm/warning flag is set to true.
Data Ready state Bar This field indicates that the transceiver has achieved
power up and data is ready. This is set to true if data
is ready to be sent and set to false if data is being
transmitted.
Rx LOS state This is the digital state of the Rx_LOS output pin. This
is set to true if the operating status is down.
Tx Fault state This is the digital state of the Tx Fault output pin.
Rate Select state This is the digital state of the SFP rate_select input
pin.