Command Line Reference Guide
keepalive
Send keepalive packets periodically to keep an interface alive when it is not transmitting data.
S5000
Syntax
keepalive [seconds]
To stop sending keepalive packets, use the no keepalive command.
Parameters
seconds
(OPTIONAL) Enter the number of seconds between keepalive
packets. The range is 0 to 23767. The default is 10 seconds.
Defaults Enabled.
Command Modes INTERFACE
Command History
Version 9.0(1.3) Introduced on the S5000.
Usage
Information
When you configure keepalive, the system sends a self-addressed packet out of the
configured interface to verify that the far end of a WAN link is up. When you configure no
keepalive, the system does not send keepalive packets and so the local end of a WAN link
remains up even if the remote end is down.
monitor interface
Monitor counters on a single interface or all interfaces on a stack-unit. The screen is refreshed every five seconds and
the CLI prompt disappears.
S5000
Syntax
monitor interface [type slot/port | stack-unit unit-number]
To disable monitoring and return to the CLI prompt, press the q key.
Parameters
interface
type
slot/port
(OPTIONAL) Enter the interface keyword followed by the
interface type and slot/port or number information. Valid slot numbers
are 0-11. The valid port numbers for each interface type are listed
below.
• For a 10-Gigabit Ethernet interface, enter the keyword
tengigabitethernet followed by slot/port numbers.
The port range is 0 to 63.
• For a 40-Gigabit Ethernet interface, enter the keyword
fortyGigE followed by slot/port numbers. The ports are 48,
52, 56, and 60.
• For the management port, enter the keyword
managementethernet followed by the slot (0-1) and the
port (0).
506