Command Line Reference Guide

operator (OPTIONAL) Enter one of the following logical operand:
eq = equal to
neq = not equal to
gt = greater than
lt = less than
range = inclusive range of ports (you must specify two ports
for the port command)
port port
Enter the application layer port number. Enter two port numbers if
using the range logical operand. The range is 0 to 65535.
The following list includes some common TCP port numbers:
23 = Telnet
20 and 21 = FTP
25 = SMTP
169 = SNMP
destination
Enter the IP address of the network or host to which the packets are
sent.
mask
Enter a network mask in /prefix format (/x) or A.B.C.D. The mask,
when specified in A.B.C.D format, may be either contiguous or non-
contiguous.
count (OPTIONAL) Enter the keyword count to count packets processed
by the filter.
byte (OPTIONAL) Enter the keyword byte to count bytes processed by
the filter.
order (OPTIONAL) Enter the keyword order to specify the QoS priority for
the ACL entry. The range is 0 to 254 (where 0 is the highest priority
and 254 is the lowest; lower order numbers have a higher priority) If
you did not use the keyword
order, the ACLs have the lowest order
by default (255).
monitor (OPTIONAL) Enter the keyword monitor when the rule is describing
the traffic that you want to monitor and the ACL in which you are
creating the rule is applied to the monitored interface. For more
information, refer to the “Flow-based Monitoring” section in the Port
Monitoring chapter of the
FTOS Configuration Guide
.
fragments Enter the keyword fragments to use ACLs to control packet
fragments.
Defaults Not configured.
Command Modes CONFIGURATION-EXTENDED-ACCESS-LIST
Command History
Version 9.0(1.3) Introduced on the S5000.
193