Command Line Reference Guide
the internal forwarding path is effectively the switch fabric
and forwarding engine.
• Down-MEP: monitors the forwarding path external to another
bridge.
domain [
name
|
level
]
Enter the keyword domain and then enter the domain name or
domain level.
ma-name
name
Enter the keyword ma-name and then enter the name of the
maintenance association.
mepid
mep-id
Enter an MEP ID. The range is 1 to 8191.
Defaults none
Command Modes INTERFACE
Command History
Version 9.0(1.3) Introduced on the S5000.
ethernet cfm mip
Create a maintenance intermediate point (MIP).
S5000
Syntax
ethernet cfm mip domain {name | level} ma-name name
Parameters
domain [
name
|
level
]
Enter the keyword domain and then enter the domain name or
domain level.
ma-name
name
Enter the keyword ma-name and then enter the name of the
maintenance association.
Defaults none
Command Modes INTERFACE
Command History
Version 9.0(1.3) Introduced on the S5000.
140