Command Line Reference Guide

Command History
Version 9.0(1.3) Introduced on the S5000.
Usage
Information
You cannot enter this command on a Master or Standby unit.
The system reboots when the off-line diagnostics complete. This is an automatic process. A
warning message appears when the offline stack-unit command is implemented.
Warning - Diagnostic execution will cause stack-unit to reboot
after completion of diags.
Proceed with Offline-Diags [confirm yes/no]:y
Related
Commands
show environment – views the S5000 component status (for example, temperature, voltage).
online stack-unit
Place a stack unit in the online state.
S5000
Syntax
online stack-unit unit-number
Parameters
stack-unit
unit-
number
Enter the keywords stack-unit followed by the unit number. The
range is 0 to 11.
Defaults none
Command Modes EXEC Privilege
Command History
Version 9.0(1.3) Introduced on the S5000.
Usage
Information
You cannot enter this command on a Master or Standby unit.
The system reboots when the off-line diagnostics complete. This is an automatic process. A
warning message appears when the offline stack-unit command is implemented.
Warning - Diagnostic execution will cause stack-unit to reboot
after completion of diags.
Proceed with Offline-Diags [confirm yes/no]:y
Related
Commands
show environment – views the S5000 system component status (for example, temperature,
voltage).
1321