Command Line Reference Guide

Command History
Version 9.0(1.3) Introduced on the S5000.
Usage
Information
A user-configurable number of downstream interfaces in an uplink-state group are put into a
link-down state with an UFD-Disabled error message when one upstream interface in an
uplink-state group goes down.
If all upstream interfaces in an uplink-state group go down, all downstream interfaces in the
same uplink-state group are put into a link-down state.
Related
Commands
downstream – assigns a port or port-channel to the uplink-state group as a
downstream interface.
uplink-state-group – creates an uplink-state group and enables the tracking of
upstream links.
enable
Enable uplink state group tracking for a specific UFD group.
S5000
Syntax
enable
To disable upstream-link tracking without deleting the uplink-state group, use the no enable
command.
Defaults Upstream-link tracking is automatically enabled in an uplink-state group.
Command Modes UPLINK-STATE-GROUP
Command History
Version 9.0(1.3) Introduced on the S5000.
Related
Commands
uplink-state-group – creates an uplink-state group and enables the tracking of
upstream links.
show running-config uplink-state-group
Display the current configuration of one or more uplink-state groups.
S5000
Syntax
show running-config uplink-state-group [group-id]
1273